Quantum-composers 9250 Series Manual de usuario

Busca en linea o descarga Manual de usuario para Generadores Quantum-composers 9250 Series. Quantum Composers 9250 Series User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 51
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
9250 Manual Version 1.2 | Quantum Composers
1
Emerald 9250
Series
Pulse
G
ener
a
t
or
Operating
M
anual
Quantum Composers, Inc.
P.O. Box 4248
Bozeman, MT 59772
1.800.510.6530
www.QuantumComposers.com
sales@QuantumComposers.com
Vista de pagina 0
1 2 3 4 5 6 ... 50 51

Indice de contenidos

Pagina 1

9250 Manual Version 1.2 | Quantum Composers 1 Emerald 9250 Series Pulse Generator Operating Manual

Pagina 2 - Contents

9250 Manual Version 1.2 | Quantum Composers 10 Channel Timer Functions The Channel Timer functions as a non-retriggerable, delayed, one sho

Pagina 3

9250 Manual Version 1.2 | Quantum Composers 11 Navigating the 9250 Primary control of the 9250 is carried out either through the 9250 applicat

Pagina 4

9250 Manual Version 1.2 | Quantum Composers 12 *Example in which initial delay jumps will not occur while actively updating while pulsing:

Pagina 5 - 1. Introduction

9250 Manual Version 1.2 | Quantum Composers 13 5. 9250 Setup Overview The 9250 can easily be interfaced by means of the included 9250 applica

Pagina 6 - 2. Safety Issues

9250 Manual Version 1.2 | Quantum Composers 14 Driver Installation (Windows XP) 1. Plug the 9250 into the computer using a USB cable. Make

Pagina 7 - Front Panel

9250 Manual Version 1.2 | Quantum Composers 15 6. 9250 Application 9250 Application Overview Aside from using the SCPI command protocol, the

Pagina 8 - Back Panel

9250 Manual Version 1.2 | Quantum Composers 16 Basic Operation The following steps must be carried out before communication with the 9250 ma

Pagina 9 - System Timer Functions

9250 Manual Version 1.2 | Quantum Composers 17  Pulse Mode: Changes the system’s output mode to Continuous, Single Shot, Burst, or Duty Cycle

Pagina 10 - Digital Output Multiplexer

9250 Manual Version 1.2 | Quantum Composers 18 Channels Section The Channels Section of the 9250 application only affects the 9250’s channel

Pagina 11 - Smooth Transition Updating

9250 Manual Version 1.2 | Quantum Composers 19 o Burst Counts: Selects the number of pulses to output with each input clock pulse. Valid inp

Pagina 12

9250 Manual Version 1.2 | Quantum Composers 2 Contents 1. INTRODUCTION ...

Pagina 13 - 5. 9250 Setup

9250 Manual Version 1.2 | Quantum Composers 20 Virtual Channels The 4 “Virtual Channels” are used solely for multiplexing purposes (see Figu

Pagina 14

9250 Manual Version 1.2 | Quantum Composers 21 Enhanced Options Shown below in Figure 6.5 is the “Enhanced Options” section of the 9250 applica

Pagina 15 - 6. 9250 Application

9250 Manual Version 1.2 | Quantum Composers 22 Command Terminal The Command Terminal Section on the 9250 application shown below (Figure 6.6

Pagina 16 - Basic Operation

9250 Manual Version 1.2 | Quantum Composers 23 Recalling Custom Settings from a Bin The 9250 series has the capability to recall any of the 6 c

Pagina 17

9250 Manual Version 1.2 | Quantum Composers 24 Figure 6.9 –9250 Application: Example

Pagina 18 - Channels Section

9250 Manual Version 1.2 | Quantum Composers 25 7. Operating the 9250 Normal Internal Rate Generator Operation The 9250 has a complete set of

Pagina 19

9250 Manual Version 1.2 | Quantum Composers 26 Single Shot Mode Pressing the unit’s Run/Stop button generates a single pulse with every pres

Pagina 20 - Virtual Channels

9250 Manual Version 1.2 | Quantum Composers 27  Within the Channel section: o Set channel mode to Normal. o Set the Sync Source to T0 in e

Pagina 21 - Enhanced Options

9250 Manual Version 1.2 | Quantum Composers 28 Pressing the unit’s Run/Stop button will place the unit into active mode and generate a sing

Pagina 22 - Parameter Storage

9250 Manual Version 1.2 | Quantum Composers 29 Pressing the unit’s Run/Stop button will place the unit into active mode and generate a pulse tr

Pagina 23 - 9250 Application Example

9250 Manual Version 1.2 | Quantum Composers 3 Recalling Custom Settings from a Bin ...

Pagina 24

9250 Manual Version 1.2 | Quantum Composers 30 Using the External Gate to Control the System The external input configured in System Gate mo

Pagina 25 - 7. Operating the 9250

9250 Manual Version 1.2 | Quantum Composers 31 Output Examples The following figure presents a graphical representation of the channel modes as

Pagina 26 - System Duty Cycle Function

9250 Manual Version 1.2 | Quantum Composers 32 8. Programming the 9250 Personal Computer to 9250 Communication The 9250 uses USB as the st

Pagina 27 - Channel Timer Overview

9250 Manual Version 1.2 | Quantum Composers 33 Line Termination The pulse generator uses text-style line terminations. When a command is sent t

Pagina 28 - Channel Duty Cycle Mode

9250 Manual Version 1.2 | Quantum Composers 34 SCPI Command Format SCPI commands control and set instrument specific functions such as setti

Pagina 29 - External Input Overview

9250 Manual Version 1.2 | Quantum Composers 35 SCPI Parameter Types The following parameter types are used: <Numeric Value> Accepts all

Pagina 30

9250 Manual Version 1.2 | Quantum Composers 36 To start the pulses use either of the following commands: :PULSE0:STATE ON <cr> <lf

Pagina 31 - Output Examples

9250 Manual Version 1.2 | Quantum Composers 37 9250 SCPI Command Summary Command Keyword 1 Keyword 2 Keyword 3 Parameter Range Notes :INSTrume

Pagina 32 - 8. Programming the 9250

9250 Manual Version 1.2 | Quantum Composers 38 :PERiod 40[ns] – 4000[s] Sets the T0 period. The command should be sent without units. I

Pagina 33 - SCPI Command Keywords

9250 Manual Version 1.2 | Quantum Composers 39 :NCOUnts 1-15 Number of periods to average. :COUNt? Reports the number of clock counts be

Pagina 34 - SCPI Optional Keywords

9250 Manual Version 1.2 | Quantum Composers 4 12. APPENDIX D – SAFETY SYMBOLS...

Pagina 35 - Programming Examples

9250 Manual Version 1.2 | Quantum Composers 40 :CMODe NORMal / SINGle / BURSt / DCYCle Allows the user to select the pattern of output

Pagina 36

9250 Manual Version 1.2 | Quantum Composers 41 :ENable 0/1 or OFF/ON Turns on/off Bluetooth module. Disables Bluetooth transmitter. This sta

Pagina 37 - 9250 SCPI Command Summary

9250 Manual Version 1.2 | Quantum Composers 42 9. Appendix A – Specifications 9250 Specifications  Indoor use in dry conditions only 

Pagina 38

9250 Manual Version 1.2 | Quantum Composers 43 Channel Timing Generator Pulse Width Range 8n - 4,000 s Width Accuracy (1) 10ns + [0.0001 x (wid

Pagina 39

9250 Manual Version 1.2 | Quantum Composers 44 Output Module Output Impedance - 50 - Ohms Output Level 3.3 – 5.0 VDC into ≥ 1K ohm 1.7 – 2.

Pagina 40 - *Note: commas should be

9250 Manual Version 1.2 | Quantum Composers 45 10. Appendix B – Bluetooth Option Overview The Bluetooth wireless communications capability is

Pagina 41 - IEEE 488.2 Common Commands

9250 Manual Version 1.2 | Quantum Composers 46  When the Bluetooth device is properly paired, connect to the 9250 on a Windows based PC by

Pagina 42 - 9250 Specifications

9250 Manual Version 1.2 | Quantum Composers 47 11. Appendix C – TZ50 (Impedance Match Option) TZ50 Overview This “TZ50” option allows a user

Pagina 43 - Trigger/Gate Input Module

9250 Manual Version 1.2 | Quantum Composers 48 Terminating Into 50 Ohms The following figure shows a typical pulse when set to 5V upon being

Pagina 44 - General

9250 Manual Version 1.2 | Quantum Composers 49 12. Appendix D – Safety Symbols Safety Marking Symbols This section provides a description of

Pagina 45 - Overview

9250 Manual Version 1.2 | Quantum Composers 5 1. Introduction This manual is a reference designed to familiarize you with the Quantum Compose

Pagina 46

9250 Manual Version 1.2 | Quantum Composers 50 IEC 417, No. 5172 Class II Equipment protected by double insulation or reinforced insulation

Pagina 47 - TZ50 Specifications

9250 Manual Version 1.2 | Quantum Composers 51 13. Appendix E – CE Declaration of Conformity .

Pagina 48 - Terminating Into 50 Ohms

9250 Manual Version 1.2 | Quantum Composers 6 2. Safety Issues Normal use of test equipment presents a certain amount of danger due to ele

Pagina 49 - Safety Marking Symbols

9250 Manual Version 1.2 | Quantum Composers 7 3. Front & Back Panel Overview Front Panel Indicators A total of 6 separate LED indicators

Pagina 50

9250 Manual Version 1.2 | Quantum Composers 8 Back Panel Indicators A total of 4 LED indicators are included on the back panel of the 9250.

Pagina 51

9250 Manual Version 1.2 | Quantum Composers 9 4. Pulse Concepts and Pulse Generator Operations Counter Architecture Overview *Start sourc

Comentarios a estos manuales

Sin comentarios