Quantum-composers 9200 Series Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 58
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
Page 24 9200 Manual Version 1.6 | Quantum Composers
Single Shot Mode
Pressing the units Run/Stop button generates a single pulse with every press. Set the
following parameters in the 9200 application:
Within the System section:
o Select Single Shot mode.
Within the Channel section:
o Set channel mode to Normal.
o Enter the required pulse width and delay. Repeat for each output channel.
o Enable the corresponding channels by clicking Enabled in the 9200 application.
Pressing the units Run/Stop button will now generate one pulse out of every enabled channel.
System Burst Mode Function
The Run/Stop button generates a stream of NT
0
pulses, where the N is specified by the
Burst parameter. The rate is specified by the Period parameter. Pressing the Run/Stop button
while the burst is in process will stop the output. After the burst has been completed, Pressing
the Run/Stop button will generate another burst of pulses. To generate a burst of pulses set
the following parameters in the 9200 application:
Within the System section:
o Select mode to be Burst.
o Set the Burst Count parameter field to produce the number of pulses desired
o Set the desired Period.
Within the Channel section:
o Set channel mode to Normal.
o Enter the required pulse width and delay. Repeat for each output channel.
o Enable the corresponding channels by clicking Enabled in the 9200 application.
Pressing the units Run/Stop button will now generate the predefined burst of pulses out of
every enabled channel.
System Duty Cycle Function
The Run/Stop button starts a continuous stream of T
0
pulses, which repeats for N pulses On
and Mpulses Off, where Nand M are specified by the On/Off parameters respectively. The
rate at which the pulses are generated is controlled by the Period parameter. To generate a
stream of pulses which will repeat for ‘N pulses On and M pulses, set the following
parameters in the 9200 application:
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 57 58

Comentarios a estos manuales

Sin comentarios