Page 36 9200 Manual Version 1.6 | Quantum Composers
9200 SCPI Command Summary
Command
Keyword 1
Keyword 2
Keyword 3
Parameter
Range
Notes
:INSTrument
The units upper level command
keyword.
:CATalog
?
Returns a comma separated list
of the names of all channels.
Example: A two channel unit
would return T
0
, CHA, CHB
:FULL
?
Returns a comma-separated list
of the names of all the channels
and their associated number.
Example: a two channel unit
would return T
0
, 0, CHA, 1, CHB,
2
:COMMands
?
Returns an indentured list of all
valid SCPI commands
:NSELect
0 4
Selects a channel using the
numeric value
:SELect
T
0
/ CH[A-D]
Selects a channel using the
identifier
:STATe
0/1 or OFF/ON
Enables/Disables the selected
channel output. If no channel
has been selected the command
is applied to T
0.
If T
0
is selected
all outputs are affected.
Enabling T
0
is the same as
pressing the RUN button.
Command
Keyword 1
Keyword 2
Keyword 3
Parameter Range
Notes
:PULSe[0]
Command to change the
units global settings, this is
the same as using the
:SPULse command
:STATe
0/1 or OFF/ON
Enables/Disables the output
for all channels. This
command is the same as
pressing the Run/Stop button.
:PERiod
200[ns] 1000[s]
Sets the T
0
period. The
command should be sent
without units. If for example
200ns is desired the
parameter sent should be
200e-9, or the decimal
equivalent.
:MODe
NORMal/SINGle/
BURSt/DCYCle
Changes the system output
mode.
:BCOunter
1-1,000,000
Changes the number of
pulses to output when the
system is in burst mode.
*Note: The commas should
be omitted.